If the robot is still not in a correct position for load identification, the robot
will slowly move to the correct position. Press
Move
to start the movement.
Note
Axis 1 to 3 must not be more than 10 degrees from proposed position.
13 The robot can go through the load identification movements slowly before
performing the load identification (slow test). Tap
Yes
if you want a slow test
and
No
to proceed to the identification.
Note
This is useful for ensuring that the robot will not hit anything during the
identification. However, this will take a lot longer time.
Note
If the load identification is planned to be run in manual full speed, then the
slow test is required before the actual measurement can start.
14 The setup for load identification is now complete. To start the motion, switch
to Automatic mode and Motors On. Then tap
Move
to start the load
identification movements.
15 When the identification is finished, switch back to manual mode, press the
three-position enabling device and the Start button. Tap
OK
to confirm.
16 The result of the load identification is now presented on the FlexPendant.
For robots that support the
Load diagram check
functionality, there is a
message if the load is approved or not, and an
Analyze
button to view more
information.
17 Tap
Yes
to update the selected tool or payload with the identified parameters.
Tap
No
to exit LoadIdentify without saving the parameters.
Load diagram check
For robots that support the
Load diagram check
functionality, the combination of
the arm load, tool and payload, will be assessed against the load diagram. The
ratings of total handling weight as well as of the center of gravity distance to the
load diagram in Z and L directions will be provided both for wrist-up and wrist-down
configurations.
There is a message if the load is approved or not, and an
Analyze
button to view
more information.
•
Load approved
•
Load not approved
•
Load approved only with wrist down
Continues on next page
170
Operating manual - OmniCore
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
6 Programming and testing
6.10.6 Load identification service routine
Continued
Summary of Contents for OmniCore S Series
Page 1: ...ROBOTICS Operating manual OmniCore ...
Page 8: ...This page is intentionally left blank ...
Page 22: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 60: ...This page is intentionally left blank ...
Page 64: ...This page is intentionally left blank ...
Page 208: ...This page is intentionally left blank ...
Page 234: ......
Page 235: ......