68 Electrical installation: input / output
Digital inputs - general purpose DIN4 - DIN9
Location: OPT1, pin 3 (CREF0), pin 4 (DIN7), 5 (DIN6), 6 (DIN5), 7 (DIN4), 11 (DIN9),
12 (DIN8), 13 (CREF1)
These general purpose digital inputs are buffered by a TLP280 opto-isolator, allowing
the input signals to be connected with either polarity. Inputs DIN4 and DIN5 share a
common reference, CREF1. Inputs DIN6 - DIN9 share a common reference, CREF0.
When the MicroFlex e150 is connected to Mint WorkBench, the digital inputs can be
configured using the Digital I/O tool. Alternatively, Mint keywords including
DRIVEENABLEINPUT
,
RESETINPUT
,
ERRORINPUT
and
STOPINPUT
can be used.
The state of the digital inputs can be viewed using the Mint WorkBench Spy window's
Axis tab. See the Mint help file for details.
General purpose digital input - DIN4 shown:
Digital input - typical connections from an ABB NextMove e100:
33R
33R
3k3
Vcc
DGND
7
13
CREF1
DIN4
MicroFlex
e
150
OPT1
TLP280
UDN2982
Mint
OUTX(0)
MicroFlex
e
150
USR GND
DOUT0
CREF1
7
10k
TLP280
13
10
1
9
DIN4
USR V+
X11
OPT1
NextMove e100 / controller
User
supply
24 V
User
supply
GND
Summary of Contents for MicroFlex e150
Page 1: ...ABB motion control User s manual MicroFlex e150 servo drive MN1961WEN ...
Page 4: ......
Page 20: ...20 Introduction to the manual ...
Page 26: ...26 Hardware description ...
Page 32: ...32 Mechanical installation ...
Page 42: ...42 Planning the electrical installation ...
Page 116: ...116 Start up ...
Page 126: ...126 Fault tracing ...
Page 152: ...152 Technical data EtherCAT Conformance Test Certificate ...
Page 162: ...162 Technical data ...
Page 178: ...178 Appendix Safe Torque Off STO STO function TüV certificate ...