30 Mechanical installation
Effects of mounting surface and proximity
The proximity of the MicroFlex e150 to other
components could affect cooling efficiency. If the
MicroFlex e150 is mounted beside another
MicroFlex e150 (or other obstruction), there
should be a minimum space of 15 mm (0.6 in) to
maintain effective cooling.
If the MicroFlex e150 is mounted above or below
another MicroFlex e150 (or other obstruction),
there should be a minimum space of 90 mm
(3.5 in) to maintain effective cooling. Remember
that a MicroFlex e150 will be receiving air that has
been already heated if it is mounted above
another MicroFlex e150 or heat source. Multiple
MicroFlex e150 units mounted above each other
should be aligned, not offset, to promote air flow
across the heat sinks.
It is recommended to allow approximately 60 mm
(2.4 in) at the front to accommodate wiring and
connectors.
15 mm
15 mm
90 mm
1
1
Metal backplane
F
o
rc
ed
ai
r fl
ow
Co
ol
War
m
Ho
t
Fan
Fan
Summary of Contents for MicroFlex e150
Page 1: ...ABB motion control User s manual MicroFlex e150 servo drive MN1961WEN ...
Page 4: ......
Page 20: ...20 Introduction to the manual ...
Page 26: ...26 Hardware description ...
Page 32: ...32 Mechanical installation ...
Page 42: ...42 Planning the electrical installation ...
Page 116: ...116 Start up ...
Page 126: ...126 Fault tracing ...
Page 152: ...152 Technical data EtherCAT Conformance Test Certificate ...
Page 162: ...162 Technical data ...
Page 178: ...178 Appendix Safe Torque Off STO STO function TüV certificate ...