![ABB MicroFlex e150 User Manual Download Page 51](http://html.mh-extra.com/html/abb/microflex-e150/microflex-e150_user-manual_2741051.webp)
Electrical installation: AC input, motor and brake 51
24 V control circuit supply
A 24 V DC supply must be provided to power the controlling electronics. This is
useful for safety reasons where AC power is removed from the power stage, but the
controlling electronics must remain powered to retain position and I/O information.
A separate fused 24 V supply should be provided for the MicroFlex e150. If other
devices are powered from the same 24 V supply, a filter (part FI0014A00) should be
installed to isolate the MicroFlex e150 from the rest of the system. Alternatively, a
ferrite sleeve can be attached to the supply cable near connector X2.
24 V filter
(optional)
Use a twisted pair cable,
with ferrite sleeve attached
close to connector X2.
Ferrite
sleeve**
STAR
POINT
Incoming safety
earth/ground (PE)
Customer supplied
24 V DC
Fuse *
* Recommended fuse: Bussman S504 20 x 5 mm anti-surge 2 A.
** Recommended ferrite sleeve: Fair-Rite part 0431164281 or similar.
X2
+24 V
GND
Summary of Contents for MicroFlex e150
Page 1: ...ABB motion control User s manual MicroFlex e150 servo drive MN1961WEN ...
Page 4: ......
Page 20: ...20 Introduction to the manual ...
Page 26: ...26 Hardware description ...
Page 32: ...32 Mechanical installation ...
Page 42: ...42 Planning the electrical installation ...
Page 116: ...116 Start up ...
Page 126: ...126 Fault tracing ...
Page 152: ...152 Technical data EtherCAT Conformance Test Certificate ...
Page 162: ...162 Technical data ...
Page 178: ...178 Appendix Safe Torque Off STO STO function TüV certificate ...