120 Fault tracing
LED flash periods
The following diagram shows the definitions of the terms ‘blinking’, ‘flashing’ and
‘flickering’ used in the previous sections, as defined by the EtherCAT Technology
Group.
LED flash timing definitions:
NET RUN (Green)
Off: INITIALISATION state (or not powered).
Blinking: PRE-OPERATIONAL state.
1 flash: SAFE-OPERATIONAL state.
3 flashes: Device identification. This state can be set from the master to locate the
device.
Continuously illuminated, not flashing: Node in OPERATIONAL state. EtherCAT is
operating normally.
200 ms
1 s
1 s
1 s
1 s
1 s
Off
1 flash
2 flashes
Inverted 2 flashes
3 flashes, etc.
Blinking
Flickering
On
(Not illuminated)
(Continuously illuminated)