![ABB MicroFlex e150 User Manual Download Page 109](http://html.mh-extra.com/html/abb/microflex-e150/microflex-e150_user-manual_2741109.webp)
Start-up 109
Performing test moves - continuous jog
This section tests the basic operation of the drive and motor by performing a
continuous jog. To stop a move in progress, click the red stop button or the drive
enable button on the toolbar. Alternatively, use the Mint WorkBench ‘Red Stop Button’
feature.
1. Check that the Drive enable button is
pressed (down).
2. In the Toolbox, click the Edit & Debug
icon.
3. Click in the Command window.
Type:
JOG(0)=10
This will cause the motor to move
continuously at 10 units per second.
In Mint WorkBench, look at the Spy
window located on the right of the screen. Check that the axis tab is selected. The
Spy window's Velocity display should show 10 (approximately). If there seems to
be very little motor movement, it is probably due to the scale factor. In the
Commissioning Wizard, on the Select Scale Factor page, if you did not adjust the
scale factor then the current unit of movement is feedback counts per second.
Depending on the motor's feedback device, 10 feedback counts per second could
equate to a very small velocity. Issue another JOG command using a larger value,
or use the Operating Mode Wizard to select a suitable scale factor (e.g. 4000 if
the motor has a 1000 line encoder, or 10,000 for a 2500 line encoder).
4. To stop the test, type:
STOP(0)
5. If you have finished testing click the
Drive Enable button to disable the
drive.
Summary of Contents for MicroFlex e150
Page 1: ...ABB motion control User s manual MicroFlex e150 servo drive MN1961WEN ...
Page 4: ......
Page 20: ...20 Introduction to the manual ...
Page 26: ...26 Hardware description ...
Page 32: ...32 Mechanical installation ...
Page 42: ...42 Planning the electrical installation ...
Page 116: ...116 Start up ...
Page 126: ...126 Fault tracing ...
Page 152: ...152 Technical data EtherCAT Conformance Test Certificate ...
Page 162: ...162 Technical data ...
Page 178: ...178 Appendix Safe Torque Off STO STO function TüV certificate ...