Electrical installation: AC input, motor and brake 49
Power disconnect and protection devices
A power disconnect should be installed between the input power supply and the
MicroFlex e150 for a fail-safe method to disconnect power. The MicroFlex e150 will
remain in a powered condition until all input power is removed from the drive and the
internal bus voltage has depleted.
The MicroFlex e150 must have a suitable input power protection device installed,
preferably a fuse. Recommended circuit breakers are thermal magnetic devices (1 or
3 phase as required) with characteristics suitable for heavy inductive loads (C-type
trip characteristic). Circuit breaker or fuses are not supplied - see
Recommended
fuses, circuit breakers and wire sizes
on page
136
. For CE compliance, see
Technical
data
on page
153
.
NOTE:
Metal conduit or shielded cable should be used. Connect conduits so the use
of a line reactor or RC device does not interrupt EMI/RFI shielding.
Using 2 phases of a 3-phase supply
Power can be derived by connecting two phases of an appropriate three-phase
supply (L1 and L2 for example). When supplying AC power in this way, the voltage
between the two phases must not exceed the rated input voltage of the
MicroFlex e150. A two pole breaker must be used to isolate both lines. Fuses must
be fitted in both lines.
L
N
L
N
L
N
L
N
From
supply
Circuit breaker
From
supply
Fuse
Circuit breaker and fuse, single-phase
L1
L1
L2
L2
L3
L3
L1
L1
L2
L2
L3
L3
From
supply
Circuit breaker
From
supply
Fuse
Circuit breaker and fuse, three-phase
Summary of Contents for MicroFlex e150
Page 1: ...ABB motion control User s manual MicroFlex e150 servo drive MN1961WEN ...
Page 4: ......
Page 20: ...20 Introduction to the manual ...
Page 26: ...26 Hardware description ...
Page 32: ...32 Mechanical installation ...
Page 42: ...42 Planning the electrical installation ...
Page 116: ...116 Start up ...
Page 126: ...126 Fault tracing ...
Page 152: ...152 Technical data EtherCAT Conformance Test Certificate ...
Page 162: ...162 Technical data ...
Page 178: ...178 Appendix Safe Torque Off STO STO function TüV certificate ...