![ABB IRBT 2005 Product Manual Download Page 141](http://html.mh-extra.com/html/abb/irbt-2005/irbt-2005_product-manual_5098141.webp)
Illustration/Note
Action
xx1400001570
Push firmly with one hand on top of the grease
pump. With the other hand, hold the black base
and turn counterclockwise.
2
Pull the transparent housing and open it.
3
Closing the grease pump
Illustration/Note
Action
xx1400001571
Hold the cranked black base, put on the trans-
parent housing and turn it clockwise.
1
When the closed position is reached you
should hear a "click".
2
Installing a new grease cartridge
Respect the following instructions to replace the grease cartridge:
Illustration/Note
Action
Open the MEMOLUB
®
as described before.
1
xx1400001572
Pull-up the black rubber seal. Fill-in the
MEMOLUB
®
with a manual grease pump. This
manual operation is required only if the
MEMOLUB
®
has been used without a cart-
ridge, if the previous cartridge has run out of
grease. Place the pump nipple at the entry of
the MEMOLUB
®
, and pump until you see
grease coming out at the outlet. Two strokes
of the manual pump are usually enough.
2
Continues on next page
Product manual - IRBT 2005
141
3HAC051130-001 Revision: F
© Copyright 2015 - 2018 ABB. All rights reserved.
2 Installation and commissioning
2.8.1 Replacing the grease cartridge in grease pump MEMOLUB
®
EPS
Continued
Summary of Contents for IRBT 2005
Page 1: ...ROBOTICS Product manual IRBT 2005 ...
Page 8: ...This page is intentionally left blank ...
Page 44: ...This page is intentionally left blank ...
Page 148: ...This page is intentionally left blank ...
Page 284: ...This page is intentionally left blank ...
Page 286: ...This page is intentionally left blank ...
Page 289: ......