![ABB IRB 7600 - 500/2.55 Product Manual Download Page 229](http://html1.mh-extra.com/html/abb/irb-7600-500-2-55/irb-7600-500-2-55_product-manual_3686220229.webp)
4 Repair
4.3.1. Replacement of cable harness, axes 1-4
227
3HAC022033-001 Revision: E
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
8. Secure the cable gland (A) with four attachment
screws (B) from inside the SMB recess.
Secure the correct attachment plate (C) to the
cable gland with its two attachment screws, using
locking liquid.
Refit the velcro strap (D).
NOTE!
Different robot versions are fitted with different
versions of the attachment plate. Make sure the
correct one is used to avoid cable failure.
Locking liquid is specified in
Required equipment on page 222
.
xx0300000560
•
A: Cable gland
•
B: Attachment screws, cable
gland
•
C: Attachment plate
•
D: Velcro strap
Action
Note
Continued
Continues on next page