4 Repair
4.3.1. Replacement of cable harness, axes 1-4
3HAC022033-001 Revision: E
224
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
10. Remove
•
the
cable gland
(A), by removing the
four attachment screws from inside
the SMB recess (B)
•
the
attachment plate
(C), by
removing the attachment screws
and the velcro strap (D).
NOTE!
Different robot versions are fitted with
different versions of the attachment plate.
When replacing the cable harness, make
sure the correct one is used to avoid cable
failure.
xx0300000560
•
A: Cable gland
•
B: Attachment screws, cable gland
•
C: Attachment plate
•
D: Velcro strap
11. Remove the cable gland securing the
cables inside the lower arm.
Action
Note
Continued
Continues on next page