![ABB IRB 7600 - 500/2.55 Product Manual Download Page 100](http://html1.mh-extra.com/html/abb/irb-7600-500-2-55/irb-7600-500-2-55_product-manual_3686220100.webp)
2 Installation and commissioning
2.5.11. Installation of cooling fan for motors, axes 1-3 (option)
3HAC022033-001 Revision: E
98
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
7. Secure the
cable bracket
to the bracket of the
robot cabling inside the frame.
Run the cable underneath the robot cabling and
out through the side of the frame, at motor, axis 1
. The correct cable run is shown in the figure to the
right!
NOTE!
There is a risk of the balancing device damaging
the cable if it is not protected by the robot cabling!
xx0500002174
A. Cable bracket. Also shown
cabling for axis 1 or 2 on
page 96
8. Connect the connector R3.FAN2 to the fan of axis
1or 2.
NOTE!
Fans on both axis 1 and 2 can not
be used at the same time!
9. Connect the connector R1.SW2/3 to the base of
the robot. Make sure that the cabling, run through
the frame and base, is not twisted and runs freely
from the robot cabling.
10. Refit the rear cover plate to the robot base.
11. Install additional cabling to and inside the
controller.
Also make adjustments in RobotWare, as
described in the following procedure.
Cabling is specified in section
Position switch and fan cables,
robot base to controller (option) on
page 120
Cable is specified in section
Fan
cables, robot base to control
cabinet (option)
.
Action
Note
Continued
Continues on next page