3 Maintenance
3.3.1. Inspection, oil level gearbox axis 1
137
3HAC022033-001 Revision: E
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
Inspection through the oil plug, inspection
The procedure below details how to inspect the oil level, axis 1 gearbox, when the oil plug
for inspection (shown in the figure
Location of gearbox on page 135
)
is available
.
Action
Note
1.
WARNING!
Handling gearbox oil involves several safety risks.
Before proceeding, please observe the safety
information in section
during work with gearbox oil on page 40
.
2.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
3. Open the
oil plug, inspection
.
Shown in the figure
4. Required oil level: max 10 mm below the oil plug
hole!
5. Add oil if required.
Art. no. is specified in
!
6. Refit the oil plug, inspection.
Tightening torque: 24 Nm.
7.
WARNING!
Do not mix the oil types! If wrong oil is refilled, the
gearbox must be rinsed as detailed in section
WARNING - Mixed oils may cause severe damage
to gearbox! on page 41
Continued