2 Installation and commissioning
2.6.5. Installation of position switches (option)
3HAC022033-001 Revision: E
108
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
2.6.5. Installation of position switches (option)
General
Position switches can be installed on axes 1-3. The position switches include cams as shown
in the figures below.
The position switch kits may be delivered in one of two ways:
•
Fitted by ABB Robotics on delivery. In this case, the cams must still be fitted and
locked by the user. For axis 1, the cover for the cams must also be fitted.
•
As kits to be completely fitted to the robot and adjusted by the user.
Required equipment
Description
Art. no.
Note
Position switch, axis 1
3HAC15715-1
Includes position swtich and plate for
customer connections.
Position switch, axis 2
3HAC15715-2
Includes only the position switch.
Position switch, axis 3
3HAC15715-3
Includes only the position switch.
Cabling, position switches and
cooling fans, axes 1, 2 and 3
3HAC15390-1
Cabling to be installed on the robot.
Plate for customer connections
3HAC025778-001
An additional connection plate must
be fitted to the robot base, if not
already installed. The plate is shown
in the figure
Additional cabling to and inside
the controller
-
Specified in section
and connection points on page 119
Connector kit R1.SW1
3HAC17252-1
Connector kit R1.SW2/3
3HAC17253-1
Continues on next page