4 Repair
4.3.1. Replacement of cable harness, axes 1-4
3HAC022033-001 Revision: E
222
©
Co
py
rig
h
t 200
4 - 20
08 ABB.
All r
ig
h
ts r
e
se
rv
ed
.
Required equipment
Removal, cable harness, axes 1-4
The procedure below details how to remove the cable harness, axes 1-4.
H
Connectors at motor 5; R3.FB5 and R3.MP5
J
Connectors at motor 6; R3.FB6 and R3.MP6
K
Rear cover plate
L
Connector R1.MP
M
Connector R1.SMB
N
Connection of earth cable
Equipment, etc.
Spare part no.
Art. no.
Note
Cable harness, axes 1-4
3HAC12782-1
Brake release located at
base.
Cable harness, axes 1-4
3HAC14940-1
Brake release located in
frame.
Locking liquid
Loctite 638
Used to secure the
attachment screws for the
attachment plate inside the
frame.
Standard toolkit
-
The content is defined in
section
Other tools and
procedures may be
required. See references
to these procedures in the
step-by-step instructions
below.
These procedures include
references to the tools
required.
Circuit Diagram
See chapter
Circuit
diagram
.
Action
Note
1. In order to facilitate refitting of cable
harness, run the robot to the specified
position:
•
Axis 1: 0 °
•
Axis 2: 0 °
•
Axis 3: 0 °
•
Axis 4: 0 °
•
Axis 5: +90 °
•
Axis 6: no significance
Axes 2 and 3 may be tilted slightly to
improve access.
Continued
Continues on next page