Note
Action
xx1800003618
Check the cabling status.
Make sure the cabling is in vertical state and is
not twisted.
2
xx1800003012
Reconnect the connectors.
•
FB4
•
MP4
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Refitting the housing cover
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Gasket for housing cover:
3HAC061959-007
xx1900002180
For robots with protection class IP67 (option
3350-670)
For robots with protection type Clean Room
(option 3351-4)
Check the gasket.
Replace if damaged.
2
Continues on next page
Product manual - IRB 1100
547
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 motor
Continued