Note
Action
xx1800003317
Inspect the cable harness status.
The cable harness must be in vertical state as
shown in the figure.
•
If the cable harness twists towards left,
proceed to step
.
•
If the cable harness twists towards right,
proceed to step
.
2
0
°
60
°
120
°
240
°
180
°
300
°
xx1800003318
Cable harness twisting towards left
Jog the axis 4 anti-clockwise (with the operator
facing the rear) until the cable harness is in vertic-
al state.
3
Continues on next page
718
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
6 Calibration
6.3.1 Updating revolution counters on OmniCore robots
Continued