Note
Action
xx1900002186
For robots with protection class IP67 (option
3350-670)
For robots with protection type Clean Room
(option 3351-4)
Check the gasket.
Replace if damaged.
2
Reconnecting the SMB connectors
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
1
For robots with protection type Clean Room
2
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Tightening torque: 0.3 Nm
xx1800002468
Reconnect the connectors.
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
4
Continues on next page
Product manual - IRB 1100
613
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.8.1 Replacing the axis-1 gearbox
Continued