Note
Action
xx1800002996
Remove the screws and washers.
5
Carefully lift out the motor.
6
xx1800002997
Remove the timing belt from its groove on the
motor.
7
Refitting the motor
Use these procedures to refit the axis-6 motor.
Refitting the axis-6 motor
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
•
all assembly surfaces are clean and without
damages
•
the motor is clean and undamaged.
2
Continues on next page
568
Product manual - IRB 1100
3HAC064992-001 Revision: L
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.7.6 Replacing the axis-6 motor
Continued