Procedure
1. Prepare the wires that are mentioned below. Refer to section
2. Loosen the screws of the terminal block X3.
3. Connect the below listed wires from the outlets. Use the illustration above as a
reference:
Outlet
Wire
Connect to terminal
1
(A) L1 wire
X3-1
(B) L2 wire
X3-2
(C) L3 wire
X3-3
(D) PE wire
X4-4
2
(E) L1 wire
X3-5
(F) L2 wire
X3-6
(G) L3 wire
X3-7
(H) PE wire
X3-8
3
(I) L1 wire
X3-9
(J) L2 wire
X3-10
(K) L3 wire
X3-11
(L) PE wire
X3-12
4
(M) L1 wire
X3-13
(N) L2 wire
X3-14
(O) L3 wire
X3-15
(P) PE wire
X3-16
4. Tighten the screws to the correct torque. For the specification, refer to section
.
4
1 2 3
5 6 7
9 10 11
13 14 15
8
12
16
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
-X3
Installation
44
HVC 200/300/360-EN | 002