3.3.3
Power cabinet, inside
J
J
I
A
K
C
D
B
E
E
C
H
F
G
A
AC contactor
B
AC input fuses
C
PE busbar
D
AC plate
E
Cable inlet
F
DC plate
G
CAN2ETH board
H
DC output busbars
I
DC door
J
AC protection covers
K
Precommissioning switch
Part
Function
AC contactor
To connect the AC power
AC input fuses
To protect the device from a power disruption
PE busbar
To connect PE cables
AC plate
To connect the AC and the precommissioning ca-
bles
Cable inlet
Opening for the cables
DC plate
To connect the interlock and LED cables
CAN2ETH board
To connect the Ethernet cables
DC output busbars
To connect the DC output power cables
Precommissioning switch
To start or stop the precommissioning mode
Description
HVC 200/300/360-EN | 002
23