Intended use of WAN and LAN ports
The WAN port is a public network interface to the controller, typically connected
to the factory network with a public IP address provided by the network
administrator.
The LAN ports are intended for connecting network based process equipment to
the controller, for example industrial networks, cameras, and welding equipment.
LAN 2 can only be used as a private network to the IRC5 controller.
xx1900002386
Connecting to the IRC5 controller
Connect an Ethernet cable between the robot controller LAN2 port and the TPS/i
welder Ethernet port. The following illustration shows an overview of the computer
unit.
xx1900002385
LAN2
X4
Continues on next page
14
Application manual - Fronius TPS 320i/400i/500i/600i with RI-FB inside/i interface
3HAC065012-001 Revision: C