7.3.2 Accessing the Fronius service port from ABB controller
Accessing the Fronius service port
Follow these steps to access the Fronius web page from the IRC5 service port:
xx2100000478
1 Define the Fronius network settings (192.168.125.165), see
. This will set the service port of the power supply
to the IRC5 private network.
2 Connect the X4 Lan 2 to an Ethernet switch, see
3 Connect the Fronius Ethernet IP and service port to the Ethernet switch/hub.
4 Open the Fronius add-in from RobotStudio.
5 From the add-in, you can access the web browser and update the synergic
lines, see
Adding or removing synergic lines from RobotStudio on page 83
82
Application manual - Fronius TPS 320i/400i/500i/600i with RI-FB inside/i interface
3HAC065012-001 Revision: C
© Copyright 2004-2021 ABB. All rights reserved.
7 Fronius EtherNet/IP configuration
7.3.2 Accessing the Fronius service port from ABB controller