Description
Parameter
The distance during which the heat data is active at the start of
the weld.
Heat Dist / Heat as time
If the parameter
Heat as time
is active the distance will be re-
placed by time (in seconds).
The welding speed during the heat phase at the start of the
weld phase.
Heat Speed
Not selected – Select weld parameters during ignition phase
manually.
Use Weld Phase Mode
Selected – Use the parameters from the
Weld
tab. This is the
default mode.
The job (schedule) that should be selected within the welder.
Job number
The information displayed in the
Job number
is:
Job number, Job name.
This is the wire feed speed (Power). In this mode, the wire feed
speed can be adjusted in the range of +/- 20 % in 1% incre-
ments.
Wire Feed Speed
This parameter represents the arc length (Voltage).
Arc Length Correction
In this mode, the Arc Length Correction can be adjusted in the
range of +/- 10 steps in 0.1 increments.
Continues on next page
Application manual - Fronius TPS 320i/400i/500i/600i with RI-FB inside/i interface
53
3HAC065012-001 Revision: C
© Copyright 2004-2021 ABB. All rights reserved.
4 Weld editor interface
4.4 Weld editor in Job mode with correction
Continued
Summary of Contents for Fronius TPS 320i
Page 1: ...ROBOTICS Application manual Fronius TPS 320i 400i 500i 600i with RI FB inside i interface ...
Page 6: ...This page is intentionally left blank ...
Page 28: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 86: ......
Page 87: ......