![ABB AKD-10 Installation And Maintenance Manual Download Page 35](http://html.mh-extra.com/html/abb/akd-10/akd-10_installation-and-maintenance-manual_2063035.webp)
Aux Switch (NO contact)
Aux Switch
Aux Switch
Aux Switch (NC contact)
Aux Switch (NO contact)
Aux Switch
Aux Switch
Aux Switch (NC contact)
Aux Switch (NO contact)
Aux Switch (NC contact)
(Note 1) AUX Switch (common)
Shunt Trip (NO contact)
Shunt Trip (NC contact)
(Note 1) Shunt Trip (common)
Bell Alarm (NO contact)
Bell Alarm (NC contact)
Bell Alarm (common)
Bell Alarm (NO contact)
Bell Alarm (NC contact)
Bell Alarm (common)
Closing spring charging motor
Closing spring charging motor
Close Circuit (electric bkr)*
Close Circuit
Undervoltage or Electric
Lockout
Undervoltage or Electric
Lockout
Neutral Sensor - Tap(+)
Neutral Sensor - Common(-)
Modbus (+) comment (+)
Modbus (-) comment (-)
Zone Selectivity Interlock (In+)
Zone Selectivity Interlock (In-)
Zone Selectivity Interlock (Out+)
Zone Selectivity Interlock (Out-)
Va (Voltage Conditioner)
Vb (Voltage Conditioner)
Vc (Voltage Conditioner)
(Note2) Trip Unit Aux Power
(24 Vdc+)
(Note2) Trip Unit Aux Power
(24 Vdc-)
26
27
28
29
30
31
32
33
34
35
36
10
1
2
11
12
3
4
13
5
6
7
5
6
7
14
15
16
19
20
21
8
17
9
18
22
23
24
25
Aux Switch (NO contact)
Aux Switch
Aux Switch
Aux Switch (NC contact)
Aux Switch (NO contact)
Aux Switch
Aux Switch
Aux Switch (NC contact)
10
1
2
11
12
3
4
13
Second Shunt Trip
(Note 1) Second Shunt Trip
14
5
OR
14
5
Aux Switch (NO contact)
(Note 1) Aux Switch
Aux Switch
Aux Switch (NC contact)
6
15
8
17
Remote charge Indicator**
Remote charge Indicator**
WPS-50 Fan Motor - 120Vac (H)
WPS-50 Fan Motor - 120Vac (N)
16
7
Remote Charge NC
Remote Charge NC
Spare
Spare
Spare
9
18
19
20
21
OFLO (phase A)
OFLO (phase A)
22
23
24
25
26
27
OFLO (phase B)
OFLO (phase B)
OFLO (phase C)
OFLO (phase C)
29
30
31
32
33
34
35
36
Spare
Spare
Spare
Spare
/RELT / GFA
Output- /RELT / GFA
Input+ (RELT)
Input- (RELT)
* Remote Close Accessory on manual breaker
** Remote Charge Indicator (closing springs) applies to
E/O breakers only
Notes
1. Auxiliary switch contacts are wired out if shunt trip is not
provided.
2. 24VDC auxiliary power required for RELT.
3. This drawing shows all breaker accessories. Refer to
breaker catalog number for accessories included with
the breaker.
4. Asmall number of specially wired WavePro breakers had
a Normally Closed Remote Charge Indicator switch
contact wired out to WavePro 36 Pt secondary
disconnect points C9 & C18 for use in a motor protection
circuit in AKD-10 switchgear. This functionality is not
required by the Retrofill breaker. The NMICV timer and
MC control relay's 4 parallel contacts in the switchgear
should be eliminated from the circuit. 120VAC
continuous power should be applied to WavePro/ AKD-
10 36-point secondary disconnect terminals A8 & A17.
Table 6
Legacy Wave-Pro secondary disconnect terminals and standard connections.
A-Disc Block (left side from front) C-Disc Block (right side from front)
C
Summary of Contents for AKD-10
Page 36: ...11 14 22 21 31 34 42 41 C2 C1 51 54 62 61 71 74 82 81 91 94 02 01 45 48 R1 R2 C ...
Page 38: ...C ...
Page 43: ...NOTES 1 WP WavePro fixed connection point C ...
Page 51: ...ONLY for 3200A Figure 48 Steps in Exploded Views for 3200A WPS 32 WPH 32 WPX 32 C ...
Page 52: ...ONLY for 3200A Figure 49 Steps in Exploded Views for 4000A WPS 40 WPX 40 C ...
Page 53: ...Figure 50 Steps in Exploded Views for 5000A WPS 50 WPX 50 ONLY for 3200A C ...
Page 65: ...Figure 64 Wiring of WP 4000A breaker with FAN control unit C ...
Page 74: ...Figure 75 Figure 76 WPF 16 with special 2500A Fuse WPF 16 2500A Fuse Tang Positions 74 C ...