16. Insert M8 bolt to the hole on the top part of the module and turn it clockwise. This will
help in pushing the module out. It also helps in pulling simultaneously from the handle
while turning the screw.
16
17. Pull the module out a bit (5 cm [2 in]) and install the lifting hook to the lifting hole.
17
18. Pull the whole module onto the installation stand. Keep the pipes and wires away from
the sharp edges and be careful not to damage the coolant connections.
19. Lift the module onto a pallet or other platform for transportation.
20. Install a new module in reverse order. Tightening torque for cooling connectors is 10 N·m
(7.4 lbf·ft) in room temperature (20 °C [68 °F]).
Maintenance 87