ACQ550-U1 User’s Manual
45
Control panel
motor speed to a display of conveyor speed. Parameters 3402…3405 scale
the parameter specified by 3401, parameters 3409…3412 scale the parameter
specified by 3408, etc.
•
A bar meter rather than one of the parameter values.
– Enable bar graph displays using parameters 3404, 3411
and 3418.
Bottom.
The bottom of the LCD display shows:
•
Lower corners
–
show the functions currently assigned to the two soft keys.
•
Lower middle
–
displays the current time (if configured to show the time).
Operating the drive
AUTO/HAND
–
The very first time the drive is powered up, it is in the auto control
(AUTO) mode, and is controlled from the Control terminal block X1.
To switch to hand control (HAND) and control the drive using the control panel, press
and hold the
or
button.
•
Pressing the HAND button switches the drive to hand control while keeping the
drive running.
•
Pressing the OFF button switches to hand control and stops the drive.
To switch back to auto control (AUTO), press and hold the
button.
Hand/Auto/Off –
To start the drive press the HAND or AUTO buttons, to stop the
drive press the OFF button.
Reference –
To modify the reference (only possible if the display in the upper right
corner is in reverse video) press the UP or DOWN buttons (the reference changes
immediately).
The reference can be modified in the local control mode (HAND/OFF), and can be
parameterized (using Group 11 reference select) to also allow modification in the
remote control mode.
Note:
The Start/Stop, Shaft direction and Reference functions are only valid in local
control (HAND/OFF) mode.
Parameters Mode
To change the parameters, follow these steps:
1
Select MENU to enter the main menu.
2
Select the Parameters mode with the UP/
DOWN buttons, and select ENTER to
select the Parameters Mode.
Summary of Contents for ACQ550-U1-011A-6
Page 1: ...ACQ550 User s Manual ACQ550 U1 Drives 1 200 hp ...
Page 4: ......
Page 10: ...10 ACS550 U1 User s Manual Table of contents ...
Page 42: ...42 ACQ550 U1 User s Manual Start up control with I O and ID Run ...
Page 56: ...56 ACQ550 U1 User s Manual Control panel ...
Page 68: ...68 ACQ550 U1 User s Manual Application macros ...
Page 250: ...250 ACQ550 U1 User s Manual Fieldbus adapter ...
Page 266: ...266 ACQ550 U1 User s Manual Maintenance ...
Page 314: ...314 ACQ550 U1 User s Manual Index ...