Technical data
419
ACH550-01 User's Manual
Air flow, 380…480 V drives
The following table lists the requirements for the cooling air flow
data for 380…480 V drives at full load in all ambient conditions
listed in
Ambient conditions
on page
440
.
Drive
Heat dissipation
Air flow
Noise
ACH550-01-
Frame size
W
BTU/hr
m
3
/h ft
3
/min
dB
02A4-4
R1
30
101
44
26
52
03A3-4
R1
40
137
44
26
52
04A1-4
R1
52
178
44
26
52
05A4-4
R1
73
249
44
26
52
06A9-4
R1
97
331
44
26
52
08A8-4
R1
127
434
44
26
52
012A-4
R1
172
587
44
26
52
015A-4
R2
232
792
88
52
66
023A-4
R2
337
1151
88
52
66
031A-4
R3
457
1561
134
79
67
038A-4
R3
562
1919
134
79
67
045A-4
R3
667
2278
134
79
67
059A-4
R4
907
3098
280
165
75
072A-4
R4
1120
3825
280
165
75
087A-4
R4
1440
4918
280
165
75
125A-4
R5
1940
6625
350
205
75
157A-4
R6
2310
7889
405
238
77
180A-4
R6
2810
9597
405
238
77
195A-4
R6
3050
10416
405
238
77
246A-4
R6
3260
11133
405
238
77
290A-4
R6
3850
13125
405
238
77
00467918.xls C