Configuring the Thermostat
Product Manual 2CQA 100 014 B0001
│
2018-09-28
│
13
Setting
Description
Options
Image
Max.
compressor
cycles per
hour, 2
nd
stage
Limits how often
compressor for stage
2 cooling will be
switched ON.
Limiting compressor
cycles saves energy
and reduces wear.
Stage 2 is controlled
by Y2. Compressor
is part of air-
conditioning or heat
pump.
1 to 6
in increments of 1
Max. heating
cycles per
hour, 1
st
stage
Limits how often
compressor for stage
1 heating will switch
ON. Limiting
compressor cycles
saves energy and
reduces wear. Stage
1 heat is controlled
by Y1. Compressor
is part of air-
conditioner or heat
pump.
1 to 12
in increments of 1
Max. heating
cycles per
hour, 2
nd
stage
Limits how often
compressor for stage
2 heating will be
switched ON.
Limiting compressor
cycles saves energy
and reduces wear.
Stage 2 heat is
controlled by Y2.
Compressor is part
of air-conditioner or
heat pump.
1 to 12
in increments of 1
Humidity
setpoint [%]
Defines desired
humidity percentage
when running a
humidifier or
dehumidifier.
20 to 80 in
increments of 10
Fan control
Note:
Setting
depends on type of
equipment.
Thermostat-
controlled
is safest
option. Select when
HVAC equipment
does not control fan
or if user is unsure.
Equipment-controlled
is more common.
Note:
User must
validate system
equipment has
control over fan. If
not, HVAC may
overheat/freeze as it
relies on being
•
Thermostat-
controlled
•
Equipment-
controlled