Configuring the Thermostat
Product Manual 2CQA 100 014 B0001
│
2018-09-28
│
12
Setting
Description
Options
Image
Shortcut for
the …
(multiple
settings)
For future purposes.
Will be hidden in the
next software
version.
(keep
unchanged)
Fan run time
when
manually
switched on
Setting limits time
fan is ON when user
touches Fan symbol.
•
Unlimited
•
10 minutes
•
20 minutes
•
30 minutes
•
60 minutes
Switch
Display Off at
Night
By default, display
brightness dims
automatically if room
light goes down. If
setting is set to
“Yes”, it will switch
OFF when room light
goes below certain
level.
Yes
No
Display
Brightness
Setting defines
display brightness on
Thermostat.
0 to 100 in
increments of 10
Protection:
Force cooling
if temperature
exceeds [°F]
If temperature rises
above this value
cooling will switch
ON to protect home.
86 to 104
in increments of 1
Protection:
Force heating
if temperature
falls below
[°F]
If temperature drops
below this value
heating will switch
ON to protect home.
34 to 50
in increments of 1
Compressor
lockout [°F]
For future purposes.
Will be hidden in the
next software
version.
(keep unchanged)
Heat pump
aux heat
lockout [°F]
For future purposes.
Will be hidden in the
next software
version.
(keep unchanged)
Max.
compressor
cycles per
hour, 1
st
stage
Limits how often
compressor for stage
1 cooling is switched
ON. Limiting
compressor cycles
saves energy and
reduces wear. Stage
1 is controlled by Y1.
Compressor is part
of air-conditioner or
heat pump.
1 to 6
in increments of 1