Configuring the Thermostat
Product Manual 2CQA 100 014 B0001
│
2018-09-28
│
14
Setting
Description
Options
Image
cooled/warmed by
fan.
Heat pump
remains in a
stage for a
minimum of
… [min]
Limits how often
Thermostat will
switch between 1
st
and 2
nd
stage
heating or cooling
sources.
10 to 25
in increments of 5
High cool
latch
temperature
[°F]
For future purposes.
Will be hidden in the
next software
version.
(keep
unchanged)
High cool
latch
temperature
[°F]
For future purposes.
Will be hidden in the
next software
version.
(keep
unchanged)
Heating starts
at… below
setpoint [°F]
Thermostat starts
heating if actual
temperature falls
below setpoint value.
Not relevant in ECO
mode.
32 to 50 in
increments of 1
Cooling starts
at … above
setpoint [°F]
Thermostat starts
cooling if actual
temperature
exceeds setpoint
value. Not relevant
in ECO mode.
32 to 50 in
increments of 1
Switching
delay between
heating and
cooling
If both
heating/cooling are
enabled, Thermostat
can automatically
switch between
them, i.e. if house
cools rapidly at night
after hot day. Setting
defines how quickly
system will switch
between heating and
cooling modes.
Medium is the
recommended mode.
Note:
Default mode
is “None”.
•
None: Stays in
original mode
setting until user
disables it
•
Low: Changes
immediately
between
heating/cooling,
changes can
occur frequently
•
Medium: Changes
between
heating/cooling
after a reasonable
time, approx. 30
minutes to one
hour
•
High: Waits
several hours
before switching
between
heating/cooling.
User Mode
Select which icons
are accessible from
the main screen.
•
Normal User:
All icons available
in settings menu
•
Power User:
All icons displayed