Action
Right-click on
Phoenix Contact Software PROFINET
and select
Insert Device into
Bus structure
.
7
This node now represents the IRC5 controller master.
In the
Bus Structure
window, select
Phoenix Contact Software PROFINET
to bring
up the
Device Details
window.
xx1600000030
8
These values does not have any effect on the IRC5 controller settings, but could be
filled with data to reflect the settings of the IRC5 controller that is using this configur-
ation.
Install the GSDML file for the ET200s Standard device by right-clicking in the Device
Catalog window and select
Import GSD file
.
xx1600000031
9
In this example, install the GSDML-V2.2-Siemens-ET200S-20090309.xml file.
This version of the PROFINET-IO Configurator Express support V2.2 syntax and
earlier versions for the GSDML files.
The installation of the GSDML file may take several minutes and the program might
appear to be unresponsive during that time.
Continues on next page
80
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
C Using PROFINET Configurator Express
Continued