Action
After the device has been configured, delete the modules that should be owned by
another controller.
•
Right-click on the module > click
Delete
on the shortcut menu.
The configuration should have the following appearance:
xx1500001664
2
Download the
ippnio.xml
file to the
HOME
directory of the currently used RobotWare
system in the IRC5 controller using an FTP client.
3
Configure the second controller the same way as mentioned in the above steps 1-2,
except that the other nodes should be deleted. That is, the modules owned by first
controller are deleted.
4
The second controller configuration should have the following appearance:
xx1500001665
Download the ippnio.xml file to the
HOME
directory of the currently used RobotWare
system in the second IRC5 controller using an FTP client
5
Restart both IRC5 controllers.
6
84
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
C Using PROFINET Configurator Express
Continued