Using Anybus adapter to connect two PROFINET networks
PROFINET on shared factory network and private network
To be able to use PROFINET on both the public and the private network, an Anybus
adapter must be used. If the same factory network is used both for PROFINET
communication and other communication, both the Anybus adapter and the WAN
port must be connected to the factory network. For information about the PROFINET
Anybus adapter, see
Application manual - PROFINET Anybus Device
.
WAN
Factory Network
Private
Robot Controller 1
LAN 1
Service
PLC
Robot I/O
LAN 2
LAN 3
I/O
I/O
Anybus
adapter
WAN
Private
Robot Controller 1
LAN 1
Service
Robot I/O
LAN 2
LAN 3
I/O
I/O
Public
Public
Anybus
adapter
PROFINET
PROFINET
PROFINET
PROFINET
xx1500000475
PROFINET on dedicated industrial network
If the PROFINET communication is separated from other communication, an Anybus
adapter must be connected to the PROFINET industrial network and the WAN port
must be connected to the factory network.
If the PROFINET communication shall be separated from other Ethernet
communication, an Anybus adapter must be installed and connected to the public
PROFINET industrial network and the WAN port connected to the factory network.
Continues on next page
24
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
2 Hardware overview
2.1 Main computer
Continued
Summary of Contents for 888-2
Page 1: ...ROBOTICS Application manual PROFINET Controller Device ...
Page 28: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 86: ......
Page 87: ......