4.3 Configuring the internal device
General
The internal device is pre-installed at the system startup. However, the input and
output size of the device can be changed. The size of the internal device determines
how many signals that can be attached, see
Input and output size on page 30
This section describes the recommended working procedure of configuring a
internal device. The working procedure helps to understand the dependencies
between the different steps.
Note
It is only possible to have one internal device.
Internal device configuration
Use this procedure to create and configure the internal device in the IRC5 controller,
using RobotStudio.
Note
Action
Start RobotStudio and connect to the
IRC5 controller. Request write access.
1
For more information about the paramet-
ers, see
.
Open the
Configuration Editor
and select
I/O System
.
2
xx1400002056
In the
Type
list, click
PROFINET Internal
Device
, right-click in the workspace and
select
PROFINET Internal Device
.
Edit the parameter values for the internal
device, if applicable.
•
Change the default values for
Input
Size
and
Output Size
to the de-
sired size.
Note
This step is optional, for more in-
formation see
.
Click
OK
.
3
In the
Type
list click
Signal
.
4
Add I/O signals for the internal device.
Restart the controller.
5
38
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
4 Configuring the internal device and external controller
4.3 Configuring the internal device
Summary of Contents for 888-2
Page 1: ...ROBOTICS Application manual PROFINET Controller Device ...
Page 28: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 86: ......
Page 87: ......