6.4.2 Output Offset on Destination Device
Parent
Output Offset On Destination Device
belongs to the type
Signal
, in the topic
I/O
System
.
Cfg name
TransferOutputOffset
Description
The parameter
Output Offset On Destination Device
specifies the output start bit
on the PROFINET internal device set by the transfer signal.
Prerequisites
The option
PROFINET Controller/Device
must be installed.
Limitations
The destination I/O device can only be the PROFINET internal device.
Default value
The default value is -1. This means that no
Output Offset On Destination Device
is defined.
Allowed values
The values are in the range of -1 to 65535.
Additional information
The parameter
Output Offset On Destination Device
specifies the start bit on the
internal device. And, for bits specified in a group are transferred starting with the
first bit.
64
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
© Copyright 2015-2018 ABB. All rights reserved.
6 System parameters
6.4.2 Output Offset on Destination Device
PROFINET Controller/Device