Operation and Maintenance
197
Aastra 470 as of R1.2
syd-0337/1.2 – R1.2 – 11.2011
Error display with status LED
Errors that occur during the start-up phase 1 are indicated with the status LED.
Tab. 95
Error displays during system setup 1:
Boot menu
The boot menu is shown during the start-up phase 2 (LED pattern 5 in
) during approx. 3 seconds. The boot menu allows the user to reset the IP
address data or to carry out a first start. The boot mode is exited automatically and
the startup then continues normally if no input is made within 3 seconds.
Fig. 80
Boot menu Aastra 470
Display of event messages
If an event message occurs in normal operation, the LED pattern switches from
"slowly flashing green" to "slowly flashing orange-green" and the event message is
indicated on the colour display.
Tab. 96
Display of event messages in normal operation:
Status LEDs on Ethernet interfaces
For explanations of the status LEDs on Ethernet interfaces see
.
Pattern
LED
Duration
Meaning
7
As long as the error remains
RAM test faulty
8
As long as the error remains
Boot software missing
9
As long as the error remains
CRC test boot software faulty
Pattern
LED
Duration
Meaning
11
As long as the event message exists
Event message present
O O
n
n
O R
n
n
R R
n
n