Installation
146
Aastra 470 as of R1.2
syd-0337/1.2 – R1.2 – 11.2011
Tab. 76
Connections on the Aastra DECT radio units
If an SB-8 / SB-8ANT is operated on two DSI interfaces, it is recommended always to
use two neighbouring ports.
Aastra Intelligent Net:
As the DECT systems of the individual nodes in an AIN do not run syn-
chronously, the two DSI interfaces of an SB-8 / SB-8ANT must always be
connected to the same node.
Tab. 77
Operating state display on Aastra DECT radio units
For further display variants, see
"Operating state of the Aastra DECT radio units",
4. 8. 3
IP system phones
The installation, powering and connection of the IP system phones Aastra 5360ip,
Aastra 5361ip, Aastra 5370ip, Aastra 5380ip and Aastra 2380ip are described in the
System Manual "Aastra Intelligent Net (AIN) and IP system phones".
4. 8. 4
OIP applications
The operating requirements and installation instructions for the OIP applications
Office 1560/1560IP, OfficeSuite and Office eDial are described in the System Man-
ual "Open Interfaces Platform".
RJ12 sockets Pin
Socket 1: DSI interface
Socket 2: Power supply
SB-4+
SB-8 / SB-8ANT
SB-4+ / SB-8 / SB-8ANT
1
Local power supply –
Local power supply –
Local power supply –
2
—
b2
—
3
b1
b1
—
4
a1
a1
—
5
—
a2
—
6
Local power
Local power
Local power
LED flashing (two LEDs on the SB-8)
Information
green
Operating state
red / green
Startup procedure running
orange
Transmission of DECT sequences
red
Fault
not flashing and not lit
LED switched off or radio unit defective or not in operation
6
5
4
3
2
1