background image

ENGLISH

2

Table of content

1 NOTES 

AND 

CONFORMITY 

3

1.1 

General safety instructions   .   .   .   .   .   .   .   .   .   .   .   . 3

1.2 

Declaration of incorporation for an incomplete machine  3

1.3 

About these Instructions   .   .   .   .   .   .   .   .   .   .   .   .   . 4

1.4 

Further applicable documents for customer/users   .   .   . 4

1.5 

Caution Indications   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

2 SAFETY 

PRECAUTIONS 

4

2.1 

Intended use.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

2.2 

Inappropriate use .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

2.3 Fitter 

quali

fi

 cation .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 4

2.4 

Important instructions for a safe installation .   .   .   .   .   . 4

2.5 

Checking the gate / gate system  .   .   .   .   .   .   .   .   .   . 4

2.6 

Warnings  .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

3 WARRANTY 

5

3.1 

Warranty period    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

3.2 

Prerequisites.   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

3.3 

Performance .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 5

4 GATE 

DRAWINGS 

6

PREPARATION FOR INSTALLATION 

7

5.1 

Install the gate operator    .   .   .   .   .   .   .   .   .   .   .   .   . 7

6 ELECTRICAL 

CONNECTION 

9

6.1 

Mains voltage   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 9

6.2 

Connect operator .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 9

HINGED GATE OPERATION 

10

7.1 

Instructing users   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 10

7.2 

Behaviour during a power failure .   .   .   .   .   .   .   .   .   . 10

7.3 

optional unlock by bowden cable .   .   .   .   .   .   .   .   .   . 10

TECHNICAL DETAILS DX250 SA 

11

8.1 

Internal operator wiring.   .   .   .   .   .   .   .   .   .   .   .   .   . 11

8.2 

Abbreviations for colour identiying used  .   .   .   .   .   .   . 11

9 INSPECTION 

AND 

MAINTENANCE 

11

10 OPTIONAL 

ACCESSORIES 

11

11 DISMANTLING 

AND 

DISPOSAL 

11

12 

CABLE LAYING - TRACK PLAN 

12

Copyright. 
No reproduction even in part is allowed without our permission.
All details subject to change.

Summary of Contents for DX250 SA

Page 1: ...www 4ddoors com au instructions for fitting operating and maintenance Hinge gate operator DX250 SA...

Page 2: ...arranty period 5 3 2 Prerequisites 5 3 3 Performance 5 4 GATE DRAWINGS 6 5 PREPARATION FOR INSTALLATION 7 5 1 Install the gate operator 7 6 ELECTRICAL CONNECTION 9 6 1 Mains voltage 9 6 2 Connect oper...

Page 3: ...sign should be installed in sight The producer rejects every liability regarding safety and functioning of the installation site if components of a different brand are used For maintenance and repair...

Page 4: ...by carrying out installation in accordance with our guidelines Gate systems used by the general public and equipped with a single protective device e g force limit may only be used when monitored 2 2...

Page 5: ...reover we shall accept no responsibility for the inadvertent or negligent use of the operator and the accessories nor for improper maintenance of the gate and its counterbalance 3 1 Warranty period In...

Page 6: ...SA 1000 300 L mm max kg 1500 250 2000 215 2500 200 140 253 0 382 90 A mm B mm max C mm D mm max D 140 261 50 373 90 140 264 100 370 90 140 260 150 375 90 200 147 200 417 90 200 327 0 266 110 200 309 1...

Page 7: ...k all safety and protective functions monthly Instruct all persons who use the gate system on the proper and safe use of the hinged gate operator Demonstrate and test the mechanical release as well as...

Page 8: ...ower buckle by key until related end switch is activated fix screw in the middle 5 1 8 Adjust end of travel GATE OPENED move gate into desired gate OPENED position turn upper buckle by key until relat...

Page 9: ...gate OPEN 5 end of travel switch gate CLOSED K1 K2 K3 K4 K5 K6 Z2 Z3 Z4 Z5 Z6 K1 K2 K3 K4 K5 K6 Z2 Z3 Z4 Z5 Z6 3 5 4 1 2 3 5 4 2 1 motor 1 motor 2 09 connect motors with MS1024 control board 10 B B A...

Page 10: ...event of a failure of the safety reversal a specialist must be commissioned immediately for the inspection and repair work 7 1 Instructing users Instruct all persons who use the gate system on the pro...

Page 11: ...ns plug and if applicable the plug of the emergency battery when performing all work on the gate system Safeguard the gate system against being switched on again without authorisation An inspection or...

Page 12: ...verview hinged gate NYY 5 x 1 5 mm2 10 m cable lenght NYY 5 x 2 5 mm2 10 max 20 m cable lenght 1 hinged gate operator 2 control board 3 radio receiver 4 photocell type 2 system mounted outside 5 photo...

Page 13: ...13...

Page 14: ...2905830 Rev 1 0 23 10 2014 www 4ddoors com au instructions for fitting operating and maintenance Hinge Gate operator DX250 SA...

Reviews: