2.6 Warnings

WARNING!

Danger of injury due to 
unexpected gate travel!

Incorrect assembly or handling 
of the operator may trigger 
unwanted gate travel that may 
result in persons or objects 
being trapped.

Follow all the instructions provided in this manual.
Incorrectly attached control devices (e.g. buttons) may 
trigger unwanted gate travel. Persons or objects may be 
trapped as a result.

•  Install control devices at a height of at least 1.5 m 

(out of the reach of children).

•  Fit permanently installed control devices (such as 

buttons) so that the entire area of travel of the gate is 
visible, but they are still away from moving parts.

Persons or objects may be trapped if the installed 
safety equipment fails.

•  In accordance with BGR 232, install at least one clearly 

visible and easily accessible emergency command unit 
(emergency OFF) near the gate so the gate can be 
brought to a standstill in the case of danger.

WARNING!

       

Danger of injury during gate travel!

Gate motion can lead to injuries or damage.

•  Make sure that no children play within the gate area and 

no persons or objects are in the gate‘s travel range and 
between the gate and the operator mechanics.

•  Operate the gate operator if you are within sight of the 

gate‘s area of travel and safety features are installed.

•  Monitor the gate travel until the gate has reached the 

end-of-travel position.

•  Drive or pass through remote control gate systems only 

if the gate stands still in its end-position GATE-OPEN!

3 WARRANTY

•  We shall be exempt from our warranty obligations and 

product liability in the event that the customer carries 
out his own structural alterations or undertakes improper 
installation work or arranges for same to be carried out 
by others without our prior approval and contrary to the 

fi

 tting guidelines we have provided.

•  Moreover, we shall accept no responsibility for the 

inadvertent or negligent use of the operator and the 
accessories nor for improper maintenance of the gate 
and its counterbalance.

3.1 Warranty period

•  In addition to the statutory warranty provided by the 

dealer in the sales contract, we grant the following 
warranty for parts from the date of purchase:

•  2 years for the operator mechanics, motor, motor 

control, radio equipment, accessories.

•  There is no warranty on consumables (e.g. fuses, 

batteries, lamps). 

•  Claims made under the warranty do not extend the 

warranty period. For replacement parts and repairs the 
warranty period is six months or at least the remainder 
of the warranty period.

3.2 Prerequisites

•  A claim under this warranty is only valid for the country 

in which the equipment was bought. The product 
must have been purchased through our authorised 
distribution channels.

•  A claim under this warranty exists only for damage 

to the object of the contract itself. Reimbursement 
of expenditure for dismantling and 

fi

 tting, testing of 

corresponding parts, as well as demands for lost pro

fi

 ts 

and compensation for damages, are excluded from the 
warranty. 

•  The receipt of purchase substantiates your right to claim 

under the warranty.

3.3 Performance

•  For the duration of the warranty we shall eliminate any 

product defects that are proven to be attributable to a 
material or manufacturing fault. 

•  We pledge to replace free of charge and at our 

discretion the defective goods with nondefective goods, 
to carry out repairs, or to grant a price reduction.

Damages caused by the following are excluded

:

• improper 

fi

 tting and connection

•  improper initial start-up and operation
•  external factors such as 

fi

 re, water, abnormal 

environmental conditions

•  mechanical damage caused by accidents, falls, impacts
•  negligent or intentional destruction
•  normal wear or de

fi

 cient maintenance

•  repairs conducted by unquali

fi

 ed persons

•  use of non-original parts
•  removal or defacing of the data label

Replaced parts become our property

.

Summary of Contents for DX250 SA

Page 1: ...www 4ddoors com au instructions for fitting operating and maintenance Hinge gate operator DX250 SA...

Page 2: ...arranty period 5 3 2 Prerequisites 5 3 3 Performance 5 4 GATE DRAWINGS 6 5 PREPARATION FOR INSTALLATION 7 5 1 Install the gate operator 7 6 ELECTRICAL CONNECTION 9 6 1 Mains voltage 9 6 2 Connect oper...

Page 3: ...sign should be installed in sight The producer rejects every liability regarding safety and functioning of the installation site if components of a different brand are used For maintenance and repair...

Page 4: ...by carrying out installation in accordance with our guidelines Gate systems used by the general public and equipped with a single protective device e g force limit may only be used when monitored 2 2...

Page 5: ...reover we shall accept no responsibility for the inadvertent or negligent use of the operator and the accessories nor for improper maintenance of the gate and its counterbalance 3 1 Warranty period In...

Page 6: ...SA 1000 300 L mm max kg 1500 250 2000 215 2500 200 140 253 0 382 90 A mm B mm max C mm D mm max D 140 261 50 373 90 140 264 100 370 90 140 260 150 375 90 200 147 200 417 90 200 327 0 266 110 200 309 1...

Page 7: ...k all safety and protective functions monthly Instruct all persons who use the gate system on the proper and safe use of the hinged gate operator Demonstrate and test the mechanical release as well as...

Page 8: ...ower buckle by key until related end switch is activated fix screw in the middle 5 1 8 Adjust end of travel GATE OPENED move gate into desired gate OPENED position turn upper buckle by key until relat...

Page 9: ...gate OPEN 5 end of travel switch gate CLOSED K1 K2 K3 K4 K5 K6 Z2 Z3 Z4 Z5 Z6 K1 K2 K3 K4 K5 K6 Z2 Z3 Z4 Z5 Z6 3 5 4 1 2 3 5 4 2 1 motor 1 motor 2 09 connect motors with MS1024 control board 10 B B A...

Page 10: ...event of a failure of the safety reversal a specialist must be commissioned immediately for the inspection and repair work 7 1 Instructing users Instruct all persons who use the gate system on the pro...

Page 11: ...ns plug and if applicable the plug of the emergency battery when performing all work on the gate system Safeguard the gate system against being switched on again without authorisation An inspection or...

Page 12: ...verview hinged gate NYY 5 x 1 5 mm2 10 m cable lenght NYY 5 x 2 5 mm2 10 max 20 m cable lenght 1 hinged gate operator 2 control board 3 radio receiver 4 photocell type 2 system mounted outside 5 photo...

Page 13: ...13...

Page 14: ...2905830 Rev 1 0 23 10 2014 www 4ddoors com au instructions for fitting operating and maintenance Hinge Gate operator DX250 SA...

Reviews: