ENGLISH
11
8 TECHNICAL DETAILS DX250 SA
Motor voltage
24 VDC
Current consumption
5 A
Power
80 W
Duty rating
60%
Max. torque
180 Nm
Duration gate open/close
13 - 24 sec. / 90°
Operating Temperature
-20 ÷ +60 °C
Weight
8.3 Kg
8.1 Internal operator wiring
13
M
motor
GY
BN
BU
WH
BN
-
+
1
2
3
4
5
M
F
C
C
F
C
O
C
O
M
1 2 3 4 5
motor
5
4 3
2 1
A
B
13 internal wiring
A
End-of-travel switch
gate opened
B
End-of-travel switch
gate closed
8.2 Abbreviations for colour identiying used
Abbreviations of the colours for identifying the cables,
conductors and components comply with the international
colour code according to IEC 757:
BK
black
RD
red
BN
brown
WH
white
GN
green
YE
yellow
BU
blue
GY
grey
9 INSPECTION
AND
MAINTENANCE
• The gate operator is maintenance-free.
• In the interest of your own safety, we recommend
having the gate system inspected and maintained by a
quali
fi
ed person in accordance with the manufacturer‘s
speci
fi
cations.
WARNING!
Danger of injury due to unexpected gate travel!
Unexpected gate travel can result during inspection and
maintenance work if the gate system is inadvertently
actuated by other persons.
• Disconnect the mains plug and, if applicable, the plug
of the emergency battery when performing all work on
the gate system.
• Safeguard the gate system against being switched on
again without authorisation.
An inspection or necessary repairs may only be carried
out by a quali
fi
ed person. Contact your supplier for this
purpose.
A visual inspection may be carried out by the operator.
• Check all safety and protective functions
monthly
.
• Malfunctions and/or defects at hand must be recti
fi
ed
immediately
.
• We would like to point out that any repairs not carried
out properly or with due professionalism shall render the
warranty null and void.
10 OPTIONAL ACCESSORIES
Optional accessories are not included in the scope of
delivery.
Loading of the operator by all electrical accessories:
max. 500 mA.
The following accessories are available:
• External radio receivers
• External impulse buttons (e.g. key switch)
• External code and transponder switches
• One-way photocell
• Warning lamps/warning lights
• Electric lock for post locking
• Electric lock for
fl
oor locking
• Stop plate
• Security contact-strip
• Spray-water protected junction box
11 DISMANTLING AND DISPOSAL
Note
When disassembling, observe the applicable regulations
regarding occupational safety.
Have a specialist dismantle the gate operator in the
reverse order of these instructions and dispose of it
properly.