User manual
52
www.3onedata.com
(
Figure 6.8.2.2
)
6.8.2.3 Rmon alarm
Enter into Rmon alarm information configuration interface.
Index use for marking a alarm information configuration, if the index is the same as before, it will
replace previous index.
MIB point corresponds to OID.
Alarm type adopt absolute to monitor the value of MIB target. Adopt delta to monitor the change of
MIB target value when get sample two times.
When monitor MIB value reach or pass the rising threshold value, will occur event correspond to
rising event index.
When monitor MIB value reach or pass the falling threshold value, will occur event correspond to
falling event index.
(
Figure 6.8.2.3
)
6.8.2.4 Rmon Event
Enter into Rmon information configuration interface.
Index correspond to rising event index and falling event index in RMON alarm information
configuration.
LOG: add an information in LOG table when the event was occurred.