![3onedata IES6116 Series User Manual Download Page 50](http://html.mh-extra.com/html/3onedata/ies6116-series/ies6116-series_user-manual_444370050.webp)
User manual
45
www.3onedata.com
Build Radius server between devices, the applicant will only can RADIUS database user name and
password. If you use an external RADIUS server you need to fill in the IP address and port number of the
authentication server. We need to fill in the IP address and port number of the billing server settings,
otherwise set by the accounting server IP address is empty if you need to use the AAA accounting
system.
Authentication server
Radius remote access authentication server, which is used for authentication and the IP address / domain
name that the devices can access, the default Port is 1812.
Authenticate the Shared Password.
For device access the shared secret string of authentication server.
Billing System Server Configuration
The IP address / domain name that the device can access, the default Port is 1813.
Such as the example setting, IEEE 802.1X server certificate client once every 3600 seconds. Such as the
example setting, IEEE 802.1X server certificate client once every 3600 seconds. Use a local database,
the local database description as following chapter. The client uses the MD5 authentication, the specific
settings as figure 6.7.4.