6.8.2 RMON
6.8.2.1 Rmon statistics
Enter into Rmon statistics information configuration interface.
Set up a port number as physical port, used as receive port for monitoring data information.
Index used for marking a application port, if the index is the same as before, it will replace previous
index.
Now, the monitor information can be get through SNMP managed software, WEB did not support
now.
(
Figure 6.8.2.1
)
6.8.2.2 Rmon History
Enter into Rmon history information configuration interface.
Setup a physical port, used as receive port for monitoring data information.
Index used for marking a application port, if the index is the same as before, it will replace previous
index Sample number is the item in the table need to hold, default is none, recommend: 50 pieces.
Sample interval is the time interval that gets the statistics data every two times, default is none,
recommend: 1800s.
Now, the monitor history information can be get through SNMP managed software, WEB did not
support now.