Incorrect Open Z-Gap
If there is no gap (B) between the Open Z-Gap bars (C) and the baseline (A), turn all three (3) print pad
adjustment knobs clockwise (right) 1-step and print the file again to verify that the lines do not touch. If
they touch on the second print, adjust all three (3) print pad adjustment knobs clockwise (right) 1-step and
reprint the file. Continue this procedure until there is a gap.
Reading the Print Pad Level Calibration Print
Correct Print Pad Level
The Print Pad Level is correct when each of the four (4) corner calibration points have no gaps between the
Print Pad Level calibration lines and the baselines.
NOTE: Before making any adjustments to the Print Pad Level, the Z-Gap must be
correct.
Incorrect Print Pad Level
In the illustration, there is an incorrect gap between the Print Pad Level calibration lines and the baselines
on the front of the print pad and no gap between the Print Pad Level calibration lines and the baselines on
the back of the print pad. The front of the print pad needs to be raised.