VES-1000 Series Ethernet Switch
24-4
Switch-Related Commands
24.4.1
VLAN Status Command
sw vlan status
Use this command to view the port-based VLAN settings for all ports.
The factory default port-based VLAN for the VES is shown in the next screen.
Figure 24-3 Default VLAN Settings
In this example, port 0 is the CPU port, ports 1 to 12 are the VDSL ports and ports 13 and 14 are the Ethernet
ports. The numbers in the top row denote the outgoing port for the corresponding port listed on the left (its egress
port).
This example details the VLAN settings for the VES-1012 Ethernet switch. The VES-1008A is identical however
the number of ports will only show from Ports 1-10.
Table 24-3 VLAN Key
SYMBOL DESCRIPTION
-
A hyphen denotes that this port is not a member of the associated VLAN group.
0
A zero denotes the port itself.
X
An “X” indicates a port’s egress (outgoing port).
To allow two subscriber ports to talk to each other, you must define the egress for both ports.
If you wish to daisy-chain the VES with for example, port 13 as the daisy-chain port (using a crossover Ethernet
cable) and port 14 as the uplink port (using a straight-through Ethernet cable), then you should change the VLAN
status to the following:
VLAN map:
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Port 0: O — — — — — — — — — — — — X X
Port 1: - O — — — — — — — — — — — X X
Port 2: - — O — — — — — — — — — — X X
Port 3: - — — O — — — — — — — — — X X
Port 4: - — — — O — — — — — — — — X X
Port 5: - — — — — O — — — — — — — X X
Port 6: - — — — — — O — — — — — — X X
Port 7: - — — — — — — O — — — — — X X
Port 8: - — — — — — — — O — — — — X X
Port 9: - — — — — — — — — O — — — X X
Port10: - — — — — — — — — — O — — X X
Port11: - — — — — — — — — — — O — X X
Port12: - — — — — — — — — — — — O X X
Port13: X X X X X X X X X X X X X O X
Port14: X X X X X X X X X X X X X X 0
Where 'O' means the port itself, 'X' means it’s VLAN member, and '-' is
not VLAN member.
ves1012>
Egress port
Port numbers
Содержание VES-1000 Series
Страница 1: ...VES 1000 Series VDSL Ethernet Switches Version 3 41 May 2004 User s Guide...
Страница 20: ......
Страница 32: ......
Страница 37: ...VES 1000 Series Ethernet Switch Web Configurator Introduction 3 5 Figure 3 4 Port Setup Example...
Страница 38: ...VES 1000 Series Ethernet Switch 3 6 Web Configurator Introduction Figure 3 5 Port Setup Edit Example...
Страница 50: ......
Страница 64: ......
Страница 72: ......
Страница 74: ......
Страница 78: ......
Страница 100: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 120: ......
Страница 128: ......
Страница 130: ......
Страница 142: ......
Страница 176: ......
Страница 178: ......
Страница 206: ......
Страница 210: ......
Страница 215: ...Appendices and Index VIII Part VIII Appendices and Index This part lists some appendices and an index...
Страница 216: ......