VES-1000 Series Ethernet Switch
20-2
System Maintenance 1
20.2.1 System
Maintenance
1.
Enter 24 from the main menu to go to
Menu 24 – System Maintenance
.
2.
Enter 1 to open
Menu 24.1 – System Status
.
3.
Enter 1 again to open
Menu 24.1.1 — System Maintenance — System Status
.
Figure 20-3 Menu 24.1.1 – System Maintenance – System Status
Figure 20-3 shows the menu screen for the VES-1012 Ethernet switch. The same screen for the VES-1008A will
show Ports 1-10.
The following table describes the fields present in
Menu 24.1 – System Maintenance – Status
.
Table 20-1 System Maintenance
–
Status Menu Fields
FIELD DESCRIPTION
Port
This refers to the VDSL or Ethernet port number. The cursor (“>“) next to a port marks the
current selected port (see commands ahead).
Link
This field shows whether the VDSL or Ethernet connection is down, the upstream/downstream
speeds of the VDSL connections and the speed/duplex mode of the Ethernet connections.
If the configured upstream and downstream rates for port 1 were 18Mbps and 16Mbps
respectively (configured in SMT menu 6.1), then we can see from menu 24.1.1 that the actual
(upstream and downstream) rates attained for port 1 with rate adaption enabled were 9Mbps
and 12Mbps respectively. Without rate adaption this link may not have established at all or it
would have established but with sporadic transmission.
State
This field shows training state of the ports. The states are
FWD
(forwarding), which means the
link is functioning normally or
STOP
(the port is stopped to break a loop or duplicate path).
TxPkts
This field shows the number of transmitted packets on this port.
RxPkts
This field shows the number of received packets on this port.
Errs
This field shows the number of received errors on this port.
Menu 24.1.1 — System Maintenance — System Status
Port
Link State TxPkts RxPkts Errs
Tx(KB/s)
Rx(KB/s)
Up
Time
> 1
9M/12M
FWD
1636800
636352
4
473
10
7:46:10
2
18M/16M FWD
3023504
0
0
8
0
22:24:04
3
Down
STOP
0 0 0
0 0 0:00:00
4
18M/16M FWD
3093495
55529
0
8
0
22:24:04
5
Down
STOP
0 0 0
0 0 0:00:00
6
Down
STOP
0 0 0
0 0 0:00:00
7
18M/16M FWD
3036539
26460
0
8
0
22:23:51
8
18M/16M FWD
3041121
16886
0
8
0
22:24:00
9
18M/16M FWD
3017116
0
0
8
0
22:24:03
10
18M/16M
FWD
109882
0 0
8 0 0:55:56
11
12M/16M FWD
3029325
11669
0
6
0
22:24:02
12
18M/16M FWD
607588
30
0
6
0
5:20:06
13
100M/F
FWD
1051300
10710950
1
11
508
72:07:19
14
100M/F
FWD
246459
9990813
0
0
10
72:07:19
Press Command:
COMMANDS: a-Reset All b-Reset d-Drop i-UP j-Down p-Detail ESC-Exit
Содержание VES-1000 Series
Страница 1: ...VES 1000 Series VDSL Ethernet Switches Version 3 41 May 2004 User s Guide...
Страница 20: ......
Страница 32: ......
Страница 37: ...VES 1000 Series Ethernet Switch Web Configurator Introduction 3 5 Figure 3 4 Port Setup Example...
Страница 38: ...VES 1000 Series Ethernet Switch 3 6 Web Configurator Introduction Figure 3 5 Port Setup Edit Example...
Страница 50: ......
Страница 64: ......
Страница 72: ......
Страница 74: ......
Страница 78: ......
Страница 100: ......
Страница 104: ......
Страница 106: ......
Страница 112: ......
Страница 120: ......
Страница 128: ......
Страница 130: ......
Страница 142: ......
Страница 176: ......
Страница 178: ......
Страница 206: ......
Страница 210: ......
Страница 215: ...Appendices and Index VIII Part VIII Appendices and Index This part lists some appendices and an index...
Страница 216: ......