2

Performance Data

Each Zoeller Pump Company 600 Series Pump installation is required to have a completed Zoeller Pump Company Start-up Report (FM0990). The 

report is to be completed by an approved Start-up Technician in the presence of the installing contractor. A copy of this report will be on file at 

the Zoeller Pump Company offices in Louisville, KY.  

Failure to comply with the requirement could void the warranty agreement. Refer to page 7 

for pumps that are kept in short term storage.

Limited Warranty

 

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used 

and maintained, for a period of one year from date of purchase by the 

end user, or 18 months from date of original manufacture of the product, 

whichever comes first.  Parts that fail within the warranty period, one 

year from date of purchase by the end user, or 18 months from the date 

of  original  manufacture  of  the  product,  whichever  comes  first,  that 

inspections determine to be defective in material or workmanship, will 

be repaired, replaced or remanufactured at Manufacturer's option, 

provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit.  No 

allowance will be made for shipping charges, damages, labor or other 

charges that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 

material or product that has been disassembled without prior approval of 

Manufacturer, subjected to misuse, misapplication, neglect, alteration, 

accident or act of nature; that has not been installed, operated or 

maintained in accordance with Manufacturer's installation instructions; 

that has been exposed to outside substances including but not limited to 

the following:  sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon 

derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive 

substances, wash towels or feminine sanitary products, etc. in all pumping 

applications.  The warranty set out in the paragraph above is in lieu of 

all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in 

connection with our products.

Contact  Manufacturer  at,  3649  Cane  Run  Road,  Louisville,  Kentucky  

40211, Attention: Customer Service Department to obtain any needed 

repair or replacement of part(s) or additional information pertaining to 

our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY 

OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow 

the exclusion or limitation of incidental or consequential damages, so 

the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

SEWAGE AND WASTEWATER

MODEL

Feet

Shut-off Head:

611

621

631

Meters

Gal.

Liters

5

1.5

250

946

320

1211

390

1476

10

3.0

185

700

255

965

335

1268

15

4.6

110

416

190

719

272

1030

20

6.1

35

132

125

473

200

757

25

7.6

--

--

60

227

130

492

30

9.1

--

--

--

55

208

35

10.7

--

--

--

40

12.2

--

45

13.7

50

15.2

55

16.7

60

18.2

Gal.

Liters

Gal.

Liters

22 ft.(6.7m)

29 ft.(8.8m)

34 ft.(10.4m)

--
--
--
--
--
--
--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--
--

641 (1PH)

420

1590

370

1401

319

1208

260

984

198

750

130

492

62

235

--

--

--

--

Gal.

Liters

39.5 ft.(12.0m)

--

--

--
--

--
--

641

651

661

460

1741

533

2018

--

--

410

1552

490

1855

590

2233

355

1343

445

1685

555

2101

300

1136

398

1507

510

1931

245

927

350

1325

460

1741

175

662

300

1136

410

1552

115

435

240

908

360

1363

50

189

175

662

305

1155

--

--

115

435

245

927

55

208

175

662

--

--

110

416

45

170

Gal.

Liters

Gal.

Liters

Gal.

Liters

44 ft.(13.4m)

54 ft.(16.5m)

63 ft.(19.2m)

--

--

--
--

--
--

--

--

651 (1PH)

475

1798

440

1666

395

1495

345

1306

290

1098

232

878

165

625

95

360

25

95

--

--

--

--

Gal.

Liters

46.5 ft.(14.2m)

--

--

Feet

Shut-off Head:

Meters

5

1.5

10

3.0

15

4.6

20

6.1

25

7.6

30

9.1

35

10.7

40

12.2

45

13.7

50

15.2

55

16.7

60

18.2

MODEL

LITERS

0

0

50

100

400

150

200

800

250

300

1200

350

1600

400

450

500

550

2000

650

GALLONS

5

2

10

15

4

6

20

25

8

30

10

35

12

40

14

45

50

16

55

18

60

70

FLOW PER MINUTE

TO

TAL D

YNAMIC HEAD

METERS

FEET

PUMP PERFORMANCE CURVE

MODELS 611/621/631/641/651/661

611

621

631

651

661

2400

600

65

20

641

651 1PH

641 1PH

013859

© Copyright 2023 Zoeller

®

 Co. All rights reserved.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Содержание E611

Страница 1: ...l on 600 Series pumps Should further assistance be necessary please call our Product Support Department at 1 800 928 PUMP 7867 Table of Contents Safety Instructions 1 Limited Warranty 2 Performance Da...

Страница 2: ...ther liability in connection with our products Contact Manufacturer at 3649 Cane Run Road Louisville Kentucky 40211 Attention Customer Service Department to obtain any needed repair or replacement of...

Страница 3: ...ver sufficient voltage to the pump motor But more importantly they could present a safety hazard if the insulation were to become damaged or the connection end were to fall into the sump 4 Make sure t...

Страница 4: ...ump housing Be sure that this hole is cleared during any servicing 7 Vent gases and odors to the atmosphere through vent pipe per Local and State codes 8 Secure power cord to avoid entanglement with v...

Страница 5: ...for mounting these starting components 2 All pumps require overload protection in panel Use with approved motor control that matches motor input in full load amperes with overload element s selected o...

Страница 6: ...allation All single phase models require start capacitor run capacitor and relay in the circuit to start and operate properly These components can be purchased separately or prewired in Zoeller Pump C...

Страница 7: ...teringabasinshouldbewearingaharnesswithsafetyrope extending to the surface so that they can be pulled out in case of asphyxiation Sewage water gives off methane and hydrogen sulfide gases both of whic...

Страница 8: ...h Float travel obstructed Defective or damaged float switch Magnetic starter contacts shorted Air lock check vent hole E Pump operates but delivers little or no water Check for plugged Pump housing di...

Страница 9: ...ump Company http reg zoellerpumps com N mero de modelo ___________ C digo de fecha __________ N mero de serie Bomba 1 ____________ Bomba 2 ___________ Simplex N P de Panel ___________________________...

Страница 10: ...nto lodo alquitr n hidrocarburos derivados de hidrocarburos aceite gasolina solventes etc u otras sustancias abrasivas o corrosivas toallas para lavar o productos sanitarios femeninos etc en todas las...

Страница 11: ...s bombas sumergibles con capacidad para manejar desechos s lidos de diferentes tama os tengan un dise o para entrada en la parte inferior de modo que se reduzcan los atascos y las fallas del sello Si...

Страница 12: ...or de la bomba NOTA Elagujerodeber estardebajodelacubiertadel contenedorylimpiarseperi dicamente Durantelosperiodos de funcionamiento de la bomba se ver un chorro de agua que sale del respiradero Perf...

Страница 13: ...eber ncumplirsetodoslosdem srequerimien tos de la NEC consulte los art culos 500 501 y 502 y los dem s que correspondan Instrucciones de cableado Las bombas trif sicas no son autom ticas Para su opera...

Страница 14: ...631 641 651 Y 611 621 CON REL GE DESPU S DEL 10 1 07 Roc e una capa de aceite anticorrosivo a las superficies que no est n pintadas El impulsor debe girarse cada seis meses para mantener los sellos l...

Страница 15: ...da de seguridad que llegue hasta la superficie para poder sacarlas en caso de asfixia Las aguas negras despiden gas metano y sulfuro de hidr geno que pueden ser altamente t xicos Lainstalaci nyrevisi...

Страница 16: ...quema el fusible Voltaje incorecto Fuente de poder desbalanceada Rotaci n incorrecta del motor Carga baja o nagativa Temperatura del agua demasiado alta El impulsor o el sello est n pegados mec nicam...

Страница 17: ...CAUSENT des blessures corporelles graves la mort ou des dommages mat riels importants Il avertit des dangers qui PEUVENT causer des blessures corporelles graves la mort ou des dommages mat riels impor...

Страница 18: ...ter la responsabilit en notre nom pour nos produits Prendre contact avec le Fabricant 3649 Cane Run Road Louisville KY 40211 Attention Customer Support pour obtenir des r parations des pi ces de rempl...

Страница 19: ...gues ou de trop faible capacit ne fournissent pas la tension n cessaire au moteur de la pompe et ellespeuvent tredangereusessil isolantestendommag ousil extr mit avec le branchement tombe dans un endr...

Страница 20: ...ompe dispose d un trou d vent 7 Doit tre nettoy avant le etretien Les gaz et les odeurs rejet s dansl atmosph reparletuyaud ventd apr slescodeslocaux et nationaux 8 S curiser le cordon d alimentation...

Страница 21: ...les ressources n cessaires l installation de ces composantes de d marrage 2 Toutes les pompes n cessitent une protection de surcharge dans le panneau N utiliser qu avec une commande moteur quivalente...

Страница 22: ...er une d formation permanente Installation monophas e Tous les mod les monophas s n cessitent un condensateur de d marrage un condensateur de fonctionnement et un relai dans le circuit afin de d marre...

Страница 23: ...deux tre fortement toxiques L installation et la v rification de l quipement lectrique doivent tre faites par un lectricien qualifi Il ne faut jamais soulever la pompe par le cordon d alimentation AVE...

Страница 24: ...de blocage de l impulseur CAUSES FR QUENTES B Le moteur surchauffe et d clenche la surcharge ou grille un fusible Mauvaise tension Source d alimentation d s quilibr e Mauvaise rotation du moteur Press...

Отзывы: