ZMC408SCAN Motion Controller Hardware Manual V1.5
11
24
12
NC
/
25
13
Attention:
1.
Under the default situation of 2D galvanometer, SCAN0 relates to Axis 4 and Axis
5 of 2D galvanometer, SCAN1 relates to Axis 6 and Axis 7 of 2D galvanometer.
2.
Under the default situation of 3D galvanometer, one is only supported. SCAN0
relates to Axis 4, Axis 5 and Axis 8 of 3D galvanometer.
4.1.
SCAN Galvanometer Interface Specification & Wiring
→
Specification
Item
(CLK, SYN, X, Y, Z) ±
(X, Y, Z) RETURN±
Signal type
Differential output
Differential input
Electric level standard
0-5V TTL
Max communication velocity
10Mbps
Max current
± 20mA
+5mA
Isolation method
Non-isolation
→
Wiring Reference