ZMC408SCAN Motion Controller Hardware Manual V1.5
Chapter VI EXIO Expansion IO
6.1.
EXIO Expansion IO Interface Description
EXIO expansion IO interface on ZMC408SCAN controller can be configured flexibility,
and the EXIO interface is specially used to drive a variety of lasers on the market. It
requires a special adapter board to use. And this interface cannot be connected to any
load except the special adapter board, and this interface adopts a double-row DB25
female socket.
The EXIO expansion IO interface can currently support the expansion of standard
YAG, FIBER and other laser types. The expansion module is connected through the EXIO
expansion interface, and the laser enable, laser switch, and laser energy control of the
laser are controlled after converting the TTL signal.
After the hardware wiring is completed, it is necessary to use commands to configure
the EXIO expansion interface and configure the input/output signals connected to the
expansion module.
→
Interface Definition
PIN Signal name
Signal description
Map digital input Map digital output
1
GND
Internal digital ground
output
/
/
2
EXIO_0
Expand IO 0
67