19
10.1.3 Setting Adjustable Energy
NOTICE
Non-compliance may result in material damage.
If the product setting is too soft, the energy is not entirely absorbed.
If the product setting is too hard, bouncing and excessive forces may result.
►
Observe the procedure for setting the product.
►
Adjust the product accordingly for the energy load.
NOTICE
Material damage and malfunction in case of non-compliance
If the load of the product cannot be adapted iteratively while the system is being started up, it is necessary to
select a level for the start.
►
Level 5 is not recommended for the start.
Ö
Incomplete energy absorption can cause damage to the system.
►
Please note the following information when starting with level 0:
Ö
There is a danger that the product will respond with excessive force, which can cause damage to the
product.
Ö
An overload of the structure is possible. The risk of damage to the system is less for level 0 than for level 5.
►
At the beginning, avoid any cycle time over multiple cycles until you have determined the optimum setting.
►
Loosen the countersunk screw.
Ö
This enables the knurled nut to move.
1
►
Use the knurled nut to set the desired
damping.
►
Secure the knurled nut using the
countersunk screw.
►
Tighten the countersunk screw hand-tight.
Ö
The product cannot be adjusted any more
during operation.
1
Knurled nut
►
Start with a load on the product that is as low as possible.
►
Increase the load gradually until the actual operating point of the system is reached.
►
Adjust the settings of the product iteratively.
INSTALLATION AND OPERATING INSTRUCTIONS:
PowerStop
DDOC00335 / b
EN / 2023-08-07
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com